The usual suspects, in order: the suction field does not reach part of the foundation, a major entry path was left open, the fan is undersized for tight soil, or a second foundation type was never treated. Each is diagnosable and fixable.
More detail
A disappointing verification number is information, not failure; it says the design met a house with one more trick than expected, which in Pittsburgh's stock is routine. Diagnosis runs the same sequence every time. First the gauge, to confirm the fan is pulling at spec. Then the pressure field: smoke or micromanometer readings at test holes across the slab show whether suction reaches the far corners, and a sectioned pre-war floor often reveals a zone the first point cannot serve, which calls for a second suction point. Then the openings: an unsealed coal-cellar wall, a perimeter channel breathing behind paneling, a crawl under an addition that never joined the design. Occasionally the answer is airflow mathematics, dense clay passing so little air that a higher-suction fan suits the soil better. Transparency is the standard to expect: each finding in writing, the proposed fix priced, and a fresh verification test after the revision, certified number and all. Our system repair service runs exactly this sequence, and the walkout FAQ explains the hillside case where partial pressure fields happen most.